Summary
Underwater self-leveling
epoxy mortar.
|
Methods
Click on a method's number to get a more detailed description. 28
- 34
|
|
U&V-W
Product Description
U&V-W is a high quality composite epoxy mortar specially made
for underwater concrete structure repair. It self-levels as it is
poured. U&V-W is harmless and has very low volatility organic
compounds and fast curing properties.
Application
- Bridges, Piers
- Concrete Structures Underwater
- Wastewater Plants
- Water tanks, Septic Tanks
- Humid, Marsh Locations
- Mixing equipment: Hand mixer.
- Gauge: Scales
- Application equipment: hopper for mortar pouring (diameter 100
or larger) what in diameter?
- Suitable for under-water concrete construction or operations in
damp environment.
- It does not disperse in water.
- High plastering property due to self-leveling effect.
- Non-pollution and non-toxicity.
- Various color finish possible.
Test Results
Test Methods : ASTM C 109, ASTM C 579
| Test
Item |
Test
Result |
| Compressive
Strength
(N / cm2) |
Water
Curing |
Air
Curing |
| 3
days |
7
days |
14
days |
3
days |
7
days |
14
days |
| 3,410 |
5,290 |
6,420 |
4,470 |
6,540 |
7,650 |
| Bond
Strength
(N / cm2)
|
Water
Curing |
Air
Curing |
| 3
days |
7
days |
14
days |
3
days |
7
days |
14
days |
| 2,290 |
2,830 |
3,080 |
2,970 |
3,170 |
3,280 |
Mixing Ratio
| U&V-W
Mortar |
| A |
B |
C |
D |
8 |
4 |
24 |
12 |
Directions
- Mix Type A and Type B, using a hand mixer.
- And add and mix Type C and D in order.
- Mix material using a mechanical method such as a hand mixer.
- Limit the amount of mixed material at normal temperature so that
it can be applied within 30 minutes.
- *The size of rushed aggregate should be within .5 – .75 inch depending
on thickness of the mortar applied.
It shall be sieved so as to be mixed with stone powder or fine aggregate.
- A sufficient curing is required under the temperature below 50°F.
- Do not apply at temperatures below 31°F.
- Given the container once used is already heated that might reduce
the time allowable for application, use other container in 2nd mixing.
- Protect the surface from external impact at least for 24 hours
after application, and continue the following work after checking
curing state.
- Do not use expired material.
- As the mixing ratio shall be based on weight the scale shall be
used for accurate mixing.
- The lower the temperature the higher the viscosity, thus heat
them with hot water to obtain a high viscosity.
- Refer to instruction on storage of powder or liquid-type material
for further details. If any problems persists, contact the manufacturer..
- In the event of any discrepancies between the specification and
work environment, please consult the manufacturer or designer before
application.
|