re-cfp
Product Description
RE-CFP is carbon fiber laminated panel for reinforced concrete repair,
bending reinforcement, and structural strengthening. RE-CFP is also
used for concrete structure rehabilitation to maintain sufficient
strength capabilities during the expected life of the concrete structure.
Application
- Concrete Buildings
- Bridges
- Elevated Bridges
- Chimney Stacks
- Tunnels
- Sewer Tunnels
- Harbor Structures
- Piers
- Cutter: Grinding cutter.
- Tool: Rubber scoop, roller.
- Recommended adhesive.
- High strength to weight ratio
- Non corrosive
- Non conductive
- Excellent fatigue resistance
- Good impact resistance
- Workability
Test Results
Test Methods : ASTM E 8
| Test
Item |
Test
Result |
| Tensile
Strength
( N / cm2 ) |
30,000 |
Modulus
of Elasticity
( N / cm2 ) |
2.3
x 106 |
Thermal
Elongation 1/ °C |
1
x 10-5 |
Strain
to Failure(%) |
1.9 |
Directions
- Remove defective parts and foreign material from surface.
- Repair uneven surface with recommended material.
- Apply the adhesive on panel using rubber scoop or roller.
- Install carbon fiber panel in accordance with the details on drawing.
- Take appropriate protection measure from dust generated from cutting.
- Cutting should be carried out in a way to ensure no dust or foreign
material remains on rod surface.
- No application under the temperature below 41°F.
- Mix the adhesive at the mixing ratio using a scale at 300rpm for
three minutes.
- Store in cool area and away from direct sunlight.
- Store in a way to ensure no contamination with dust or oil.
- Refer to specification for further detail on storage. Contact
the manufacturer for inquiries on storage.
- Handle carefully so as not to be damaged by impact or bending
during storage and transportation.
- In the event any discrepancies between the specification and work
environment, please consult the manufacturer or designer before
application.