Summary


Neutralization preventive coating and membrane coating.

Methods

Click on a method's number to get a more detailed description.

6 - 7 - 16 - 18 - 29 - 35 - 36 - 37


 

 

HE-300


Product Description

HE-300 is a water based epoxy polyamide membrane barrier coat of two components. It is a chemically atmospheric curing type of waterproof coating and concrete neutralization preventive. It is a highly tolerant membrane/barrier to prevent water seepage or permeation for floors, walls, water storage tanks or reservoirs and swimming pools. It is safe to use in sensitive locations (around food or habitable areas) and is environmentally friendly.

Application

    1. Basements
    2. Tunnels
    3. Roof Slabs
    4. Water Tanks
    5. Swimming Pools
    6. Water Purification Plants
    7. Sewage Treatment Facilities

Application Equiment

    1. Mixing equipment: Hand mixer.
    2. Gauge: Scales.
    3. Application equipment: Brush, roller.

Features

    1. Easy cleanup using water and can be applied to damp surfaces
    2. Cured membrane will withstand 250 kPa hydrostatic pressure which is equivalent to a 25m head of water.
    3. Can be tinted with Universal machine paint colorants.
    4. Non-flammable, negligible odor and toxicity as approved for use with drinking water tanks.
    5. Has excellent adhesion to most substrates including concrete block, brick, masonry, stone, and wood

Test Results

Test Methods: ASTM D 1654, ASTM E 154, ASTM D 3980, ASTM D 4364

Test Item
Test Result
Bond Strength
(N / cm2)
Dry Mortar
Wet Mortar
3
days
7
days
14 days
3 days
7 days
14
days
232
253
263
205
247
289
Absorption Ratio (%)
1 hour
5 hour
24 hours
0.02
0.02
0.03
Permeability Ratio (%)
0
Acid Water Resistance
(2% HCl × 20¡É ×72hrs)
No Effect
Alkali Water Resistance
(2% NaOH ×20¡É ×72hrs)
No Effect
Accelerated Weathering Resistance
(Sunshine Carbon ×120hrs)
No Effect


Mixing Ratio

HE-300
Type A
Type B
1
1


Directions

    1. Measure Type A and Type B per missing ratio.
    2. Because Type A contains filler, it may settle down when storage is extended. Make sure to thoroughly mix Type A with a hand mixer before mixing with Type B (hardener).
    3. Mix material using a mechanical method such as a hand mixer.
    4. Limit the amount of mixed material at normal temperature so that it can be applied within 40 minutes at normal temperature.
    5. In consideration that the time allowable for application tends to reduce at high temperature and increase in low temperature, the amount of material for a single application shall be controlled accordingly.
    6. The application shall, in principle, be carried out in horizontal, vertical and cross direction.

Caution

    1. A sufficient curing is required under the temperature below 50°F.
    2. Do not apply at temperatures below 31°F.
    3. Measurement shall be accurate and strictly in accordance with the mixing ratio.
    4. Do not used expired material.
    5. For waterproofing applications, use 0.5mm or thicker.

Storage

    1. Refer to instruction on storage of powder or liquid-type material for further details. If any problems persists, consult the manufacturer.

Other

    1. In the event of any discrepancies between the specification and work environment, please consult the manufacturer or designer before application.

     

The RE-Systems Group © 2008