17. Water-Leakage Deriving Pipe Installation Method
- Chip off concrete surface/water-jet cleaning
- Install PVC pipe
- Set up Backup Rods
- Apply HE-256 & Rapid hardening cement
- Adhere non-woven fabric
- Cover with wire netting
- Apply RE-PH Mortar
18. Water-Leakage Repair Method
- Chip off concrete surface/water-jet cleaning
- Apply HE-256 & Rapid hardening cement
- Brush G&W Mortar
- Apply RE-PH Mortar
- Apply HE-300
19. Crack Repair Injection Method
- Chip off concrete surface/water-jet cleaning
- Install Injection packer
- Sealing with G&W mortar
- Inject U&V-GL
- Remove injection packers
- V-cutting
- Apply Dency-P
- Fill with G&W Mortar
20. Corrosive Tunnel Repair Method
- Chip off concrete surface/water-jet cleaning
- Apply Dency-P (1 time)
- Brush G&W Mortar (1 time)
- Apply RE-PH Mortar
- Apply HE-300 (2 times)
21. Tunnel Lining Reinforcement Method
- Chip off concrete surface/water-jet cleaning
- Apply Dency-P (1 time)
- Brush G&W Mortar (1 time)
- Apply RE-PH Mortar
- Apply HE-300 (2 times)